HHD BF1022 Backflow Preventer - ASSE 1022 - 1/4 Inch Male Flare Connections

  • Model: HHD BF1022
  • Manufactured by: HHD

$178.45

Add to Cart:
The HHD BF1022 Backflow Preventer is an ASSE 1022 approved backflow prevention device designed to help protect potable water supplies from contamination caused by reverse water flow in compatible commercial beverage dispensing systems. Featuring 1/4 Inch male flare inlet and outlet connections, this compact white backflow preventer incorporates two independently acting check valves, an atmospheric vent, and an integral inlet strainer to provide protection in properly specified installations.

Distributed by Holiday House Distributing, the BF1022 is designed for commercial beverage equipment applications where backflow protection is required. Its internal check valves are biased toward a normally closed position, while a normally open atmospheric port is positioned between the check valves. A built-in 100-mesh inlet strainer helps capture particulate matter before it enters the device. Constructed from non-toxic, corrosion-resistant materials approved for potable water use, the BF1022 is rated for supply pressures up to 150 PSI and water temperatures from 33F to 130F.

Features

ASSE 1022 approved backflow preventer
Designed to help protect potable water supplies against backflow contamination
1/4 Inch male flare inlet connection
1/4 Inch male flare outlet connection
Two independently acting internal check valves
Check valves biased toward a normally closed position
Normally open atmospheric vent located between the check valves
Integral 100-mesh inlet strainer
Helps reduce the entry of particulate matter into the valve assembly
Non-toxic, corrosion-resistant construction
Approved for potable water applications as specified by HHD
Suitable for supply pressures up to 150 PSI
Operating water temperature range of 33F to 130F
White valve body
Designed for compatible commercial beverage dispensing installations
Free shipping to the lower 48 United States

Specifications

Distributor: Holiday House Distributing (HHD)
Part Number: BF1022
Product Type: Backflow Preventer
Approval Standard: ASSE 1022
Inlet Connection: 1/4 Inch Male Flare
Outlet Connection: 1/4 Inch Male Flare
Check Valve Design: Two Independently Acting Check Valves
Check Valve Position: Normally Closed
Atmospheric Port: Normally Open, Located Between Check Valves
Inlet Strainer: Integral 100-Mesh Screen
Maximum Supply Pressure: 150 PSI
Operating Water Temperature: 33F to 130F
Construction: Non-Toxic, Corrosion-Resistant Materials
Color: White
Application: Compatible Commercial Beverage Dispensing Systems
Unit of Sale: One Backflow Preventer
Shipping: Free to the Lower 48 United States

Common Applications

Commercial beverage dispensing systems requiring ASSE 1022 protection
Carbonated beverage dispensing equipment
Soda fountain water supply connections
Restaurant and foodservice beverage installations
Convenience store beverage dispensing equipment
Commercial beverage equipment water supply protection
Replacement of compatible ASSE 1022 backflow prevention devices
Water supply connections using 1/4 Inch male flare fittings
Equipment installations requiring an atmospheric vent backflow preventer
Preventive maintenance of commercial beverage water supply systems

Why Choose HHD BF1022 Backflow Preventer?

Protecting the potable water supply is an important part of commercial beverage equipment installation and maintenance. Changes in supply pressure or operating conditions can create situations where liquid attempts to flow backward through a water connection. In beverage dispensing systems, proper backflow protection is especially important because the equipment may contain ingredients or liquids that must not be allowed to enter the incoming drinking water supply.

The HHD BF1022 is designed around the requirements of ASSE 1022, a standard associated with backflow prevention devices for beverage dispensing equipment. Selecting an appropriately approved device helps installers address the backflow protection requirements of compatible commercial beverage systems.

Unlike a simple inline check valve, the BF1022 incorporates two independently acting check valves. Both are biased toward a normally closed position, providing a mechanical arrangement intended to resist reverse flow through the water supply connection. This dual-check design is an important part of the device's backflow prevention function.

A normally open atmospheric port is positioned between the two check valves. This vent is an important feature of the BF1022 design because it provides a path to atmosphere under specified operating or failure conditions. The vent must remain unobstructed and the device must be installed according to the manufacturer's instructions so the backflow protection system can function as intended.

The integral 100-mesh inlet strainer provides another useful feature for commercial beverage installations. Small particles carried by the incoming water supply can interfere with the operation of precision valve components. The built-in strainer helps capture particulate matter before it reaches the internal check valve assembly, supporting dependable operation when the device is properly maintained.

The BF1022 is constructed from non-toxic, corrosion-resistant materials suitable for potable water applications as specified by HHD. Its white body provides a distinctive appearance that can help technicians identify the device during equipment inspection and replacement.

HHD specifies a maximum supply pressure of 150 PSI and an operating water temperature range of 33F to 130F. These limits should be considered when selecting the device for a particular installation. Commercial beverage systems can have different pressure and temperature requirements, and the backflow preventer must be compatible with the operating conditions of the equipment.

The 1/4 Inch male flare inlet and outlet connections are another important selection detail. Flare connections are different from male pipe threads, female pipe threads, and compression fittings. Confirming the correct fitting configuration before ordering helps avoid installation problems, unnecessary adapters, and potential leaks.

For restaurants, convenience stores, cafeterias, and other commercial foodservice operations, maintaining properly functioning backflow prevention equipment is an important part of protecting the potable water supply. A damaged, leaking, or improperly operating device should be evaluated and replaced with a correctly specified backflow preventer.

The HHD BF1022 offers a combination of dual check valves, atmospheric vent protection, an integral inlet strainer, and ASSE 1022 approval in a compact device designed for compatible commercial beverage installations. These features distinguish it from the simpler stainless steel BFS backflow preventers and make it important to select the correct model for the required application.

Related HHD Backflow Preventers

Holiday House Distributing offers additional backflow preventers with different connection sizes, materials, and approval standards. Choose the appropriate device based on the equipment requirements, fitting configuration, and applicable plumbing codes.

HHD BF1022B - Brass Backflow Preventer, ASSE 1022, 3/8 Inch Flare x 3/8 Inch NPT
HHD BF1024 - Backflow Preventer, ASSE 1024, 3/8 Inch FPT
HHD BFS4MF4FF - Stainless Steel Backflow Preventer, 1/4 Inch Male Flare x 1/4 Inch Female Flare
HHD BFSMP4FP4 - Stainless Steel Backflow Preventer, 1/4 Inch MPT x 1/4 Inch FPT
HHD BFSFP6MP6 - Stainless Steel Backflow Preventer, 3/8 Inch FPT x 3/8 Inch MPT
HHD BFS - Stainless Steel Backflow Preventer, 1/4 Inch FPT Inlet and Outlet

The HHD BF1022 is a specialized ASSE 1022 backflow preventer designed for compatible commercial beverage dispensing systems. Its two independently acting check valves, normally open atmospheric port, integral 100-mesh strainer, and 1/4 Inch male flare connections provide a practical backflow protection solution for properly specified installations. Verify the part number, connection sizes, operating pressure, temperature limits, vent installation requirements, and applicable plumbing codes before ordering.
  1. Home
  2. Valves
  3. Strainers Back Flow Valves
  4. HHD BF1022 Backflow Preventer - ASSE 1022 - 1/4 Inch Male Flare Connections
Copyright © 2026 Discount Coffee Equipment. Powered by Zen Cart