HHD BF1022B Brass Backflow Preventer - ASSE 1022 - 3/8 Inch Flare x 3/8 Inch NPT

  • Model: HHD BF1022B
  • Manufactured by: HHD

$73.65

Add to Cart:
The HHD BF1022B Brass Backflow Preventer is an ASSE 1022 approved backflow prevention device designed to help protect potable water supplies from contamination caused by reverse water flow in compatible commercial beverage dispensing systems. Featuring 3/8 Inch flare and 3/8 Inch NPT connections, this compact brass valve provides a practical solution for beverage equipment water supply installations requiring an appropriately approved backflow prevention device.

Distributed by Holiday House Distributing, the BF1022B features durable brass construction and an atmospheric port designed to provide visual indication of secondary check valve leakage. This important feature helps maintenance technicians identify conditions that may require inspection or replacement of the backflow prevention assembly. HHD specifies a working pressure range of 10 to 200 PSI and a maximum operating water temperature of 130F. Its ASSE 1022 approval makes it suitable for compatible beverage dispensing installations where this protection standard is required.

Features

Brass backflow preventer for commercial beverage dispensing systems
ASSE 1022 approved backflow prevention device
Designed to help protect potable water supplies against reverse flow
3/8 Inch flare connection
3/8 Inch NPT connection
Durable brass valve body construction
Atmospheric port for visual indication of secondary check valve leakage
Designed for compatible beverage and soda dispensing installations
Working pressure range of 10 to 200 PSI
Maximum operating water temperature of 130F
Compact inline configuration for equipment water supply connections
Suitable for properly specified commercial foodservice applications
Useful for replacing worn or damaged ASSE 1022 backflow preventers
Designed for installation with compatible flare and pipe thread fittings

Specifications

Distributor: Holiday House Distributing (HHD)
Part Number: BF1022B
Product Type: Backflow Preventer
Valve Body Material: Brass
Approval Standard: ASSE 1022
Connection Size: 3/8 Inch Flare x 3/8 Inch NPT
Minimum Working Pressure: 10 PSI
Maximum Working Pressure: 200 PSI
Maximum Operating Water Temperature: 130F
Atmospheric Port: Visual Indication of Secondary Check Valve Leakage
Application: Compatible Commercial Beverage Dispensing Systems
Unit of Sale: One Backflow Preventer

Common Applications

Commercial beverage dispensing systems requiring ASSE 1022 protection
Carbonated beverage dispensing equipment
Soda fountain water supply connections
Restaurant and foodservice beverage installations
Convenience store beverage dispensing systems
Commercial beverage equipment water supply protection
Replacement of compatible ASSE 1022 backflow prevention devices
Water supply connections using compatible 3/8 Inch flare and NPT fittings
Maintenance of commercial beverage dispensing equipment
Plumbing installations requiring an approved atmospheric vent backflow preventer

Why Choose HHD BF1022B Brass Backflow Preventer?

Protecting the potable water supply is an important part of commercial beverage equipment installation and maintenance. Changes in water pressure or equipment operating conditions can create situations where liquid attempts to flow backward through a water connection. In beverage dispensing systems, proper backflow protection is especially important because the equipment may contain ingredients or liquids that must not enter the incoming drinking water supply.

The HHD BF1022B is designed for applications requiring ASSE 1022 backflow protection. This standard addresses backflow prevention devices used with beverage dispensing equipment. Selecting a device approved for the intended application helps installers meet equipment specifications and applicable plumbing requirements.

One of the distinguishing features of the BF1022B is its atmospheric port. HHD identifies this port as providing visual indication of secondary check valve leakage. If leakage occurs under conditions that cause the port to discharge, maintenance personnel may be able to recognize that the backflow prevention assembly requires inspection or service.

The atmospheric port is an important functional component and must remain unobstructed. The valve should be installed in the proper orientation and location according to the manufacturer's instructions, including any requirements for drainage, accessibility, and protection against water damage.

Brass construction provides a durable housing for the internal backflow prevention components. Brass is commonly used in commercial plumbing because of its strength and suitability for properly specified water supply applications. The BF1022B offers a compact alternative for installations where a brass ASSE 1022 backflow preventer is required.

HHD specifies a working pressure range of 10 to 200 PSI and a maximum operating temperature of 130F. These ratings are important when selecting a backflow preventer for commercial beverage equipment. The device must be used within its approved operating limits, and the installation must satisfy the equipment manufacturer's water supply requirements.

The 3/8 Inch flare and 3/8 Inch NPT connections distinguish BF1022B from other backflow preventers in the HHD catalog. Flare fittings and pipe thread fittings use different sealing methods and are not interchangeable. Selecting the correct connection configuration helps prevent leaks and reduces the need for unnecessary adapters.

For restaurants, convenience stores, cafeterias, and other commercial foodservice operations, properly functioning backflow prevention equipment is essential for protecting potable water connections. A damaged, leaking, or improperly operating backflow preventer should be evaluated and replaced with a correctly specified device.

Compared with the HHD BF1022, which features a white body and 1/4 Inch male flare connections, the BF1022B offers brass construction and a 3/8 Inch flare x 3/8 Inch NPT connection arrangement. These differences make it important to verify the original equipment specifications rather than selecting a replacement based solely on the ASSE 1022 designation.

The HHD BF1022B combines brass construction, ASSE 1022 approval, published operating pressure and temperature ratings, and an atmospheric port for visual leakage indication. These features make it a practical option for properly specified commercial beverage dispensing systems requiring this type of backflow protection.

Related HHD Backflow Preventers

Holiday House Distributing offers additional backflow preventers with different connection sizes, materials, and approval standards. Select the appropriate device based on the required protection level, fitting configuration, and applicable plumbing codes.

HHD BF1022 - Backflow Preventer, ASSE 1022, 1/4 Inch Male Flare
HHD BF1024 - Brass Backflow Preventer, ASSE 1024, 3/8 Inch FPT
HHD BFS4MF4FF - Stainless Steel Backflow Preventer, 1/4 Inch Male Flare x 1/4 Inch Female Flare
HHD BFSMP4FP4 - Stainless Steel Backflow Preventer, 1/4 Inch MPT x 1/4 Inch FPT
HHD BFSFP6MP6 - Stainless Steel Backflow Preventer, 3/8 Inch FPT x 3/8 Inch MPT
HHD BFS - Stainless Steel Backflow Preventer, 1/4 Inch FPT Inlet and Outlet

The HHD BF1022B Brass Backflow Preventer provides an ASSE 1022 backflow protection solution for compatible commercial beverage dispensing systems. Its brass construction, atmospheric port for visual indication of secondary check valve leakage, and 3/8 Inch flare x 3/8 Inch NPT connections make it a practical replacement option for properly specified installations. Verify the part number, connection sizes, fitting orientation, pressure and temperature requirements, installation instructions, and applicable plumbing codes before ordering.
  1. Home
  2. Valves
  3. Strainers Back Flow Valves
  4. HHD BF1022B Brass Backflow Preventer - ASSE 1022 - 3/8 Inch Flare x 3/8 Inch NPT
Copyright © 2026 Discount Coffee Equipment. Powered by Zen Cart