HHD BFVCBA4 VersaCheck Aluminum Dual Check Backflow Preventer - 1/4 Inch Female NPT

  • Model: HHD BFVCBA4
  • Manufactured by: HHD

$143.25

Add to Cart:
The Holiday House Distributing BFVCBA4 VersaCheck Dual Check Backflow Preventer by Vista Water Group is designed to help protect potable water systems against contamination caused by reverse water flow. Featuring a hardcoat anodized aluminum body and 1/4 Inch female NPT inlet and outlet connections, this compact inline valve is intended for compatible commercial beverage dispensing equipment, soda fountain systems, and foodservice water supply installations.

The VersaCheck BFVCBA4 incorporates two independently acting, spring-loaded check valves to provide dual check backflow protection. Its dark metallic finish, corrosion-resistant hardcoat anodized aluminum construction, and compact threaded design make it a practical choice for commercial beverage equipment installers, plumbing professionals, and maintenance technicians. With a stated maximum operating pressure of 200 PSI and published flow performance specifications, the BFVCBA4 is designed for applications requiring reliable backflow protection in a compact assembly.

Features

Dual check backflow preventer for compatible potable water systems
Two independently acting spring-loaded check valves
Hardcoat anodized aluminum body
Dark metallic finish
1/4 Inch female NPT inlet connection
1/4 Inch female NPT outlet connection
Helps prevent reverse water flow toward the potable water supply
Compact inline design for threaded plumbing connections
Corrosion-resistant body construction
Maximum operating pressure of 200 PSI
Lightweight design weighing approximately 2.41 Ounces
Suitable for approved commercial beverage and water supply applications
Low maintenance valve design
Published flow performance specifications
Product information lists ASSE 1024 and ASSE 1032 certifications
Product information lists NSF 61 and NSF 372 certifications
Product information lists California HSC 116875 compliance

Specifications

Distributor: Holiday House Distributing (HHD)
Manufacturer: Vista Water Group
Brand: VersaCheck
Part Number: BFVCBA4
Product Type: Dual Check Backflow Preventer
Valve Configuration: Two Independently Acting Spring-Loaded Check Valves
Body Material: Hardcoat Anodized Aluminum
Body Finish: Dark Metallic
Inlet Connection: 1/4 Inch Female NPT
Outlet Connection: 1/4 Inch Female NPT
Outside Diameter: 1.25 Inches
Overall Length: 2.75 Inches
Weight: 2.41 Ounces
Maximum Operating Pressure: 200 PSI
Maximum Operating Temperature: Verification Required
Flow Rate at 10 PSI Pressure Drop: 9.69 GPM
Flow Rate at 18 PSI Pressure Drop: 13.11 GPM
Stated Certifications: ASSE 1024, ASSE 1032, NSF 61, NSF 372
Additional Stated Compliance: California HSC 116875
Primary Applications: Commercial Beverage and Potable Water Systems

Common Applications

Commercial beverage dispensing equipment
Restaurant soda fountain systems
Commercial coffee equipment water supply lines
Foodservice beverage preparation equipment
Convenience store beverage stations
Compatible potable water plumbing installations
Approved residential water supply applications
Compatible irrigation and HVAC water connections
Replacement of existing dual check backflow preventers
New equipment installations requiring approved backflow protection

Dual Check Backflow Protection

Backflow occurs when water or other fluids reverse direction within a plumbing system. Changes in water pressure can allow downstream fluids to move back toward the potable water supply, potentially introducing unwanted substances into the upstream water line.

The VersaCheck BFVCBA4 incorporates two independently acting, spring-loaded check valves to help prevent reverse flow. Each check valve provides a separate checking element within the assembly, helping maintain the intended direction of water movement under suitable operating conditions.

This dual check design is useful for approved commercial beverage and potable water installations where this type of backflow prevention device is specified. The required level of protection depends on the connected equipment, potential contamination hazard, and applicable plumbing codes.

Hardcoat Anodized Aluminum Construction

The BFVCBA4 features hardcoat anodized aluminum construction with a dark metallic finish. This distinguishes it from the BFVCBP4, which is listed with a white Schedule 80 PVC body.

The anodized aluminum body provides a corrosion-resistant exterior and lightweight construction for compatible water handling applications. Its compact 1.25 Inch diameter and 2.75 Inch overall length make it suitable for installations where space is limited.

The product image shows the dark aluminum body, VersaCheck identification, and directional flow arrows. These markings help technicians identify the valve and determine the intended direction of water flow during installation.

Customers comparing the BFVCBA4 and BFVCBP4 should consider the different body materials, published flow characteristics, and equipment requirements when selecting the appropriate valve.

Flow Performance

The Holiday House Distributing BFVCBA4 has a stated maximum operating pressure of 200 PSI and published flow performance specifications for applications requiring a specific water flow capacity.

Flow Rate at 10 PSI Pressure Drop: 9.69 GPM
Flow Rate at 18 PSI Pressure Drop: 13.11 GPM

These distributor-provided flow values can help installers evaluate the valve for compatible beverage equipment and plumbing applications. Actual flow performance depends on the available water pressure, connected equipment, fittings, and installation conditions.

The maximum operating temperature should be confirmed with the manufacturer before installation in elevated-temperature applications because the supplied temperature specifications require additional verification.

Related Products

HHD BFVCBP4 - VersaCheck PVC Dual Check Backflow Preventer with 1/4 Inch Female NPT Inlet and Outlet
HHD BFVCBP6 - VersaCheck PVC Dual Check Backflow Preventer with 3/8 Inch Female NPT Inlet and Outlet
HHD BFVCQ4 - VersaCheck Backflow Preventer with 1/4 Inch Quick Connect Inlet and Outlet
HHD BFVCQ6 - VersaCheck Backflow Preventer with 3/8 Inch Quick Connect Inlet and Outlet
HHD BFSSHB6 - Stainless Steel Backflow Preventer with 3/8 Inch Hose Barb Inlet and Outlet

Choosing the Correct Backflow Preventer

Holiday House Distributing offers several VersaCheck backflow preventer configurations for commercial beverage and potable water systems. The BFVCBA4 features a hardcoat anodized aluminum body with 1/4 Inch female NPT inlet and outlet connections.

The BFVCBP4 offers the same nominal threaded connection size with a Schedule 80 PVC body. For installations requiring 3/8 Inch female NPT connections, the BFVCBP6 provides another available configuration.

Quick connect models BFVCQ4 and BFVCQ6 are available for applications requiring 1/4 Inch and 3/8 Inch quick connect fittings, respectively. The BFSSHB6 provides an alternative single check configuration with 3/8 Inch hose barb connections.

These products have different connection arrangements, body materials, and potentially different operating characteristics. They should not be considered directly interchangeable without confirming the requirements of the installation.

Certifications and Compliance

The supplied VersaCheck BFVCBA4 product information lists ASSE 1024, ASSE 1032, NSF 61, NSF 372, and California HSC 116875 compliance.

NSF 61 addresses drinking water system component health effects, while NSF 372 addresses lead content requirements. Applicable ASSE standards establish performance requirements for specific types of backflow prevention devices.

These are distributor-provided certification and compliance claims. Confirm the current certification listings for the exact BFVCBA4 model and intended application before installation.

Product Documentation

HHD VersaCheck Quick Reference Guide
VersaCheck Beverage Flow Curves
VersaCheck Installation and Use Guide
VersaCheck Testing Procedures
Massachusetts Approvals
Wisconsin Approvals
QAI Product Listing

Important Installation Information

Install the BFVCBA4 according to the manufacturer's installation instructions and in the correct direction of water flow. Follow the directional arrows marked on the valve body. Verify that the 1/4 Inch female NPT connections match the existing plumbing and use compatible threaded fittings and approved sealing methods.

Do not exceed the stated maximum operating pressure of 200 PSI. Confirm the manufacturer's maximum operating temperature before installing the valve in hot water or elevated-temperature applications.

Backflow prevention requirements vary depending on the potential contamination hazard, local plumbing codes, and equipment application. A dual check valve is not an acceptable substitute for every type of required backflow prevention assembly.

Inspect existing fittings and water lines when replacing an older backflow preventer. Damaged threads, improper adapters, or incompatible connections can result in leaks or installation problems.

California Proposition 65 Information

For California Proposition 65 information applicable to Holiday House Distributing products, please refer to the distributor's official information page.

Holiday House Distributing Proposition 65 Information

Reliable Backflow Protection for Commercial Beverage Equipment

The Holiday House Distributing BFVCBA4 VersaCheck Dual Check Backflow Preventer provides a practical solution for commercial beverage equipment installers, plumbing professionals, and maintenance departments requiring a compact inline backflow prevention device with 1/4 Inch female NPT connections.

Its hardcoat anodized aluminum construction, dual check valve configuration, and published flow performance make it a useful component for compatible beverage dispensing equipment, commercial coffee systems, and potable water installations. The dark metallic finish also helps distinguish this aluminum model from the white PVC version.

For customers requiring a PVC body instead of aluminum, the HHD BFVCBP4 offers another VersaCheck option with 1/4 Inch female NPT connections. Additional configurations are available with 3/8 Inch female NPT, quick connect, and hose barb fittings.

Before ordering, verify that your application requires a hardcoat anodized aluminum dual check backflow preventer with 1/4 Inch female NPT inlet and outlet connections. Confirm the required certifications, operating conditions, and local plumbing code requirements. This listing includes one Holiday House Distributing BFVCBA4 VersaCheck Backflow Preventer. Additional fittings, adapters, and installation components are sold separately.
  1. Home
  2. Valves
  3. Strainers Back Flow Valves
  4. HHD BFVCBA4 VersaCheck Aluminum Dual Check Backflow Preventer - 1/4 Inch Female NPT
Copyright © 2026 Discount Coffee Equipment. Powered by Zen Cart