HHD BFVCQ4 VersaCheck Dual Check Backflow Preventer - 1/4 Inch Quick Connect

  • Model: HHD BFVCQ4
  • Manufactured by: HHD

$59.25

Add to Cart:
The Holiday House Distributing BFVCQ4 VersaCheck Dual Check Backflow Preventer by Vista Water Group is designed to help protect potable water supplies against contamination caused by reverse water flow. Featuring 1/4 Inch push-to-connect fittings on both the inlet and outlet, this compact inline backflow preventer is ideal for compatible commercial beverage dispensing equipment, water filtration systems, and point-of-use water applications.

The VersaCheck BFVCQ4 incorporates two independently acting, spring-loaded check valves to provide dual check backflow protection. Its lightweight PVC construction, convenient quick connect fittings, and compact design make it a practical choice for beverage equipment technicians, water filtration installers, and maintenance departments. With a maximum operating pressure of 150 PSI and a maximum operating temperature of 140 F, the BFVCQ4 provides a convenient solution for compatible water supply installations requiring approved backflow protection.

Product Image Note

The product image shows two backflow preventers for illustration and product detail purposes. The BFVCQ4 is sold individually. Each order includes one backflow preventer, not two.

Features

Dual check backflow preventer for compatible potable water systems
Two independently acting spring-loaded check valves
1/4 Inch push-to-connect inlet fitting
1/4 Inch push-to-connect outlet fitting
Quick connect design for convenient tubing installation
Compact PVC construction
Helps prevent reverse water flow toward the potable water supply
Suitable for compatible beverage dispensing and water filtration systems
Designed for point-of-use water supply applications
Maximum operating pressure of 150 PSI
Maximum operating temperature of 140 F
Lightweight design weighing approximately 1.50 Ounces
Compact inline configuration for installations with limited space
Low maintenance valve design
Product information lists ASSE 1024 and ASSE 1032 certifications
Product information lists NSF 61 and NSF 372 certifications
Product information lists California HSC 116875 compliance
Sold individually

Specifications

Distributor: Holiday House Distributing (HHD)
Manufacturer: Vista Water Group
Brand: VersaCheck
Part Number: BFVCQ4
Product Type: Dual Check Backflow Preventer
Valve Configuration: Two Independently Acting Spring-Loaded Check Valves
Body Material: PVC
Inlet Connection: 1/4 Inch Push-to-Connect
Outlet Connection: 1/4 Inch Push-to-Connect
Outside Diameter: 1 Inch
Overall Length: 3.50 Inches
Weight: 1.50 Ounces
Maximum Operating Temperature: 140 F
Maximum Operating Pressure: 150 PSI
Flow Rate at 10 PSI Pressure Drop: 2.00 GPM
Stated Certifications: ASSE 1024, ASSE 1032, NSF 61, NSF 372
Additional Stated Compliance: California HSC 116875
Primary Applications: Beverage Dispensing and Point-of-Use Water Systems
Quantity: 1

Common Applications

Commercial beverage dispensing equipment
Restaurant soda fountain systems
Commercial coffee equipment water supply lines
Point-of-use water filtration systems
Water coolers and drinking water dispensers
Under-counter water supply installations
Compatible residential water filtration systems
Light commercial potable water applications
Replacement of existing quick connect backflow preventers
New beverage equipment installations requiring approved backflow protection

Dual Check Backflow Protection

Backflow occurs when water or other fluids reverse direction within a plumbing system. Changes in water pressure can allow downstream fluids to move back toward the potable water supply, potentially introducing unwanted substances into the upstream water line.

The VersaCheck BFVCQ4 uses two independently acting, spring-loaded check valves to help prevent reverse flow. Each check valve provides a separate checking element within the assembly, helping maintain the intended direction of water movement under suitable operating conditions.

This dual check configuration is useful for approved beverage dispensing and point-of-use potable water installations where this type of backflow prevention device is specified. The required level of protection depends on the connected equipment, potential contamination hazard, and applicable plumbing codes.

Quick Connect Installation Advantages

The BFVCQ4 features 1/4 Inch push-to-connect fittings on both ends, allowing appropriately sized tubing to connect directly to the valve without separate threaded adapters.

Push-to-connect fittings are especially convenient for commercial beverage equipment, under-counter filtration systems, and point-of-use water applications where installation space may be limited.

For proper installation, use tubing with the correct outside diameter and compatible material. Tubing should be cut squarely, inspected for damage, and inserted according to the manufacturer's instructions.

Unlike female NPT threaded backflow preventers, the BFVCQ4 is designed for compatible 1/4 Inch outside diameter tubing connections. Threaded and push-to-connect models should not be considered directly interchangeable without verifying the installation requirements.

Flow Performance

The Holiday House Distributing BFVCQ4 has a maximum operating pressure of 150 PSI and a maximum operating temperature of 140 F.

Flow Rate at 10 PSI Pressure Drop: 2.00 GPM

This published flow specification can help installers evaluate the valve for compatible beverage equipment and water filtration applications. Actual flow performance depends on the available water pressure, connected equipment, tubing, fittings, and installation conditions.

The compact PVC body measures approximately 1 Inch in diameter and 3.50 Inches in overall length, making it suitable for installations where space is limited.

Related Products

HHD BFVCQ6 - VersaCheck Dual Check Backflow Preventer with 3/8 Inch Quick Connect Inlet and Outlet
HHD BFVCBP4 - VersaCheck PVC Dual Check Backflow Preventer with 1/4 Inch Female NPT Inlet and Outlet
HHD BFVCBA4 - VersaCheck Aluminum Dual Check Backflow Preventer with 1/4 Inch Female NPT Inlet and Outlet
HHD BFVCBP6 - VersaCheck PVC Dual Check Backflow Preventer with 3/8 Inch Female NPT Inlet and Outlet
HHD BFVCBA6 - VersaCheck Aluminum Dual Check Backflow Preventer with 3/8 Inch Female NPT Inlet and Outlet
HHD BFSSHB6 - Stainless Steel Backflow Preventer with 3/8 Inch Hose Barb Inlet and Outlet

Choosing the Correct Backflow Preventer

Holiday House Distributing offers several VersaCheck backflow preventer configurations for commercial beverage and potable water systems. The BFVCQ4 features 1/4 Inch quick connect fittings for applications using compatible 1/4 Inch outside diameter tubing.

For installations requiring larger quick connect fittings, the BFVCQ6 provides 3/8 Inch inlet and outlet connections.

The BFVCBP4 and BFVCBA4 offer 1/4 Inch female NPT threaded connections with PVC and hardcoat anodized aluminum body options. The BFVCBP6 and BFVCBA6 provide corresponding 3/8 Inch female NPT configurations.

The BFSSHB6 is another available option featuring 3/8 Inch hose barb connections and a single check valve configuration.

These products have different connection arrangements, body materials, and potentially different operating characteristics. Always select the correct backflow preventer according to the equipment specifications and applicable plumbing requirements.

Certifications and Compliance

The supplied VersaCheck BFVCQ4 product information lists ASSE 1024, ASSE 1032, NSF 61, NSF 372, and California HSC 116875 compliance.

NSF 61 addresses drinking water system component health effects, while NSF 372 addresses lead content requirements. Applicable ASSE standards establish performance requirements for specific types of backflow prevention devices.

These are distributor-provided certification and compliance claims. Confirm the current certification listings for the exact BFVCQ4 model and intended application before installation.

Product Documentation

HHD VersaCheck Quick Reference Guide
VersaCheck Beverage Flow Curves
VersaCheck Installation and Use Guide
VersaCheck Testing Procedures
Massachusetts Approvals
Wisconsin Approvals
QAI Product Listing

Important Installation Information

Install the BFVCQ4 according to the manufacturer's instructions and in the correct direction of water flow. Verify that the tubing outside diameter is compatible with the 1/4 Inch push-to-connect fittings.

Do not exceed the maximum operating pressure of 150 PSI or maximum operating temperature of 140 F. Confirm that the valve's flow capacity and pressure drop are suitable for the connected equipment.

Backflow prevention requirements vary depending on the potential contamination hazard, local plumbing codes, and equipment application. A dual check valve is not an acceptable substitute for every type of required backflow prevention assembly.

Inspect tubing and fittings when replacing an older backflow preventer. Damaged tubing, improper insertion, or incompatible connections can result in leaks or unreliable operation.

California Proposition 65 Information

For California Proposition 65 information applicable to Holiday House Distributing products, please refer to the distributor's official information page.

Holiday House Distributing Proposition 65 Information

Convenient Backflow Protection for Beverage and Water Filtration Systems

The Holiday House Distributing BFVCQ4 VersaCheck Dual Check Backflow Preventer provides a convenient solution for commercial beverage equipment technicians, water filtration installers, and maintenance departments requiring a compact inline backflow prevention device with 1/4 Inch quick connect fittings.

Its dual check valve configuration, lightweight PVC construction, and push-to-connect design make it a practical choice for compatible soda dispensing equipment, commercial coffee systems, water coolers, and point-of-use filtration installations.

For applications requiring 3/8 Inch quick connect fittings, the HHD BFVCQ6 offers another VersaCheck option. Additional models are available with female NPT threaded connections and hose barb fittings for different installation requirements.

Before ordering, verify that your application requires a dual check backflow preventer with 1/4 Inch push-to-connect inlet and outlet fittings. Confirm the required certifications, operating conditions, and local plumbing code requirements. This listing includes one Holiday House Distributing BFVCQ4 VersaCheck Backflow Preventer. The product image shows two units for detail purposes only. Fittings, tubing, and additional installation components are sold separately.
  1. Home
  2. Valves
  3. Strainers Back Flow Valves
  4. HHD BFVCQ4 VersaCheck Dual Check Backflow Preventer - 1/4 Inch Quick Connect
Copyright © 2026 Discount Coffee Equipment. Powered by Zen Cart